Product Search


Applied Membranes (AM-99-25) RO Membrane Cleaning Chemical for Silica, Silicates Removal - 25 lbs


Applied Membranes (AM-99-25) RO Membrane Cleaning Chemical for Silica, Silicates Removal - 25 lbs
$413.99
Home Improvement

Membrane CleaningEven with all the preventative care given to a reverse osmosis system, some fouling of the membranes will take place.  Cleaning of the membranes can improve membrane performance. All membranes lose their performance with time. One of the major causes for the loss of performance is due to substances that deposit on the membrane surface.  Although the term fouling is used for deposit of any materials on the membrane, the coating of the membrane surface can be due to the following:FoulingScalingFoulingFouling of membranes is due to the suspended or emulsified materials that may be present in the feed water to the reverse osmosis system. Examples of such materials are:  silica, oil, clay, iron, sulfur and humic acids.  These substances can be present in a very fine or colloidal form.  Even the typical 5 micron cartridge filters used upstream from a reverse osmosis system may not completely remove these foulants.Membrane Fouling and ScalingThe concentration of all materials in the feed water - dissolved and suspended - is highest near the membrane surface.  As permeate is removed through the membrane, all impurities are left behind near the membrane surface.  The layer of water next to the membrane surface (boundary layer) gets more and more concentrated in the dissolved and suspended materials.  These concentrations reach a certain steady level depending on feed velocity, element recovery and membrane permeate flux (gallons per square foot of permeate produced per day).It is important to follow membrane manufacturers' recommendations on minimum feed flow, maximum element recovery and maximum element flux.  These recommendations are based on the element size and quality of feed water being treated.  The concentrations of the dissolved and suspended solids in the boundary layer control the performance of the membrane.  Higher concentrations mean higher osmotic pressure, higher tendency of suspended solids to coagulate and coat the membrane surface, and higher likelihood of scaling to take place.  Maintaining proper operating conditions for the membrane is the key preventative step to minimize membrane fouling


IsoPure Water





Applied Membranes (AM-99-5) RO Membrane Cleaning Chemical for Silica, Silicates Removal - 5 lbs
154.49
Applied Membranes (AM-99-5) RO Membrane Cleaning...
Applied Membranes M-T1512A18 RO Membrane
42.95
Applied Membranes M-T1512A18 RO Membrane
Applied Membranes M-T1812A150 RO Membrane
44.95
Applied Membranes M-T1812A150 RO Membrane
Applied Membranes M-T1812A24 RO Membrane
35.99
Applied Membranes M-T1812A24 RO Membrane
Applied Membranes M-T1812A36 RO Membrane
39.95
Applied Membranes M-T1812A36 RO Membrane
Applied Membranes M-T1812A50 RO Membrane
44.49
Applied Membranes M-T1812A50 RO Membrane
Applied Membranes M-T1812A75 RO Membrane
39.95
Applied Membranes M-T1812A75 RO Membrane
Applied Membranes (U4040PES) 4"×40" UF PES Membrane 10,000 MWCO
499.99
Applied Membranes (U4040PES) 4"×40" UF PES...
Applied Membranes M-T1512A12 Reverse Osmosis Membrane
34.99
Applied Membranes M-T1512A12 Reverse Osmosis...
Applied Membranes M-T1812A36-CUL Replacement for AMI M-T1812C36 RO Membrane
49.95
Applied Membranes M-T1812A36-CUL Replacement...
Applied Membranes M-T1812A36-CUL, Replacement Membrane for Culligan AC30
49.95
Applied Membranes M-T1812A36-CUL, Replacement...
Applied Membranes M-T1812A50 Replacement for GE Osmonics Desal TFM-50 Membrane
44.49
Applied Membranes M-T1812A50 Replacement...
Applied Membranes (M-T1812A) Replacement Residential Reverse Osmosis Membrane
49.99
Applied Membranes (M-T1812A) Replacement...
Applied Membranes (PV2521PR1000) 2.5" x 21" Fiberglass Membrane Housing Pressure Vessel 1000 PSI
722.58
Applied Membranes (PV2521PR1000) 2.5" x 21"...
Applied Membranes (PV2540PR1000) 2.5" x 40" Fiberglass Membrane Housing Pressure Vessel 1000 PSI
839.50
Applied Membranes (PV2540PR1000) 2.5" x 40"...
Applied Membranes M-T1812A24 Replacement for GE TFM-24
35.99
Applied Membranes M-T1812A24 Replacement...
Applied Membranes M-T1812A100 Replacement for GE Desal TFM-100
47.95
Applied Membranes M-T1812A100 Replacement...
Applied Membranes M-T1812A36 Replacement For GE FX12M
39.95
Applied Membranes M-T1812A36 Replacement...
Applied Membranes M-T1812A36-FIL Replacement For GE FX18M
49.95
Applied Membranes M-T1812A36-FIL Replacement...
Applied Membranes M-T1812A100 Replacement for Everpure TFM-100, 1221122
47.95
Applied Membranes M-T1812A100 Replacement...